2.3.3 Connecting and configuring sensor
2.3.3.1 Specification
In order to run sensor input DVR normally, the following conditions are required.
Spec
Input Ch. 16EA Transistor input
Input type N.C, N.O supprt
Supported sensor Dry contact sensor
Way of connecting Connecting the trimmed wire to terminal block
Performance
Available input
pulse range
Minimum 500ms
Output current Typical DC 12mA
Connecting sensor input
Connect S1 ~ S16 with referring the following image. It shows to connect a dry contact (Please
refer “Wire Handling”.